Each DSCP20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input type, measurement range, and other features are software configurable. A PC, the DSCX-887 and DSCX-416 interface cables, and the DSCX-895 configuration software are required to configure the transmitter. Communication is serial RS-232C.
The DSCP20 can interface to 12 industry standard thermocouple types: J, K, T, E, R, S, B, N, L, U, C, and D. Cold junction compensation is selectable as either internal or external. Three RTD types, Pt 100, Ni 100, and Cu 50* can be interfaced in a two, three or four wire connection. All inputs are linearized using up to 23 points of interpolation, and total errors are less than ±0.2%.
Other configurable features include: zero point and input range adjustment, output response for open or short-circuit sensor or cable failure, normal or inverted output, ripple suppression for 50Hz or 60Hz, and output time response. The DSCX-895 configuration software allows query, print-out and saving of configuration settings, display of input measurement value, and display of interpolation table points.
*Call factory for Cu RTD information.
- Low-Cost Non-Isolated 4-20mA Transmitter
- No Power Supply Required, Powered from Output Loop Current
- Interfaces to All Standard Thermocouples and RTDs
- Software Configurable Input Type and Range
- Open and Short-Circuit Input Detection
- Configurable with or without Output Loop
- Power Connected
- Mounts on Standard DIN Rail
- -25°C to +80°C Operating Temperature
- CE Compliant
DSCP20 Devices
Part Number |
Input Type | Output Type | Mechanical Format | Internal Power Supply | Isolation Voltage | Isolation Type | Accuracy | Supply Voltage |
|
RTD, Thermocouple, mV |
4 to 20 mA, or Inverted |
DIN rail |
None |
Vrms |
N/A |
<±0.1% |
Loop Powered |
Frequently Asked Questions
Can Dataforth provide calibration reports for modules I purchased?
Yes we can provide calibration reports for the modules that you purchased.
You can either
a) visit https://www.dataforth.com/TestDataReport.aspx to search for Test Report Datasheets by Serial Number or
b) you can send us a list of model numbers and their serial numbers to support@dataforth.com
How does the load resistance of a module affect the noise at the output?
Noise at the output of a module is independent of load resistance.
Due to resource constraints on my computer, I'm unable to open the three dimensional CAD models provided on your website. Does Dataforth provide two demensional CAD models for download as well?
Two dimensional CAD models can be generated upon customer request. Please contact Customer Service for assistance.
Was this content helpful?
Yes
/
No
Don't see an answer to your question?
If you have a question that is not answered here, please submit your question using our
Online Technical Support Assistance.
Dataforth offers a wide range of
custom modules for those instances when our standard commercial off-the-shelf (COTS) solutions
don't quite meet your specific application needs. Contact Customer Service and Application Support to discuss design guidelines
and design feasibility. Customer Service and Application Support can be reached at
sales@dataforth.com or +1-800-444-7644.
We are interested in your feedback regarding our products. Please let us know what you think and if you have any questions regarding the
DSCP20
and how this product could apply to your application. Your feedback is very valuable to us and very much appreciated.