LDM70-SE: Fully Isolated RS-232 Line Driver

LDM70-SE
Fully Isolated RS-232 Line Driver

Product Availability:

Description

The LDM70 series of products is designed to allow video display terminals (VDTs) and other RS-232 devices to be connected over distances sufficient to cover any industrial or institutional complex of buildings. These line drivers feature a rugged aluminum enclosure small enough to mount on the back panel of VDT units, saving valuable desk and floor space.

The LDM70 series is designed for full duplex, asynchronous operation over two DC-continuity, non-loaded, twisted-wire pairs. Through special highspeed optically coupled circuits, they may communicate at data rates up to 57,600 baud. A handshake operation is implemented over the same two-wire pairs. A self-powered model and a host-powered model are available. The self-powered unit uses 12VAC from a wall-mounted transformer, while the host-powered unit takes ±DC power from pins 9 and 10 of the RS-232 connector. The line driver circuits - and, consequently, the host device - are protected from electrical transients due to lightning strikes or operation of heavy industrial equipment.

Each device features a convenient Data-Communication Equipment (DCE) to Data-Terminal Equipment (DTE) switch which reverses pins 2 and 3 of the RS-232 connector. For installation and troubleshooting, each unit has diagnostic Light-Emitting Diodes (LEDs) on the transmit and receive lines. In addition, LEDs indicate valid carrier detect and data terminal ready.

The RS-232 connector may be ordered as a male or female 25-pin connector. Field connection is made through a modern, solderless, screw-termination assembly. Alternatively, a convenient four-wire modular phone jack (RJ-11) is available.

Features

  • DC to 57,600 Baud
  • Complete Isolation with Optical Couplers and Power DC-to-DC Converter
  • Data Terminal Ready, Carrier Detect Handshake without Extra Wires
  • Surge Protectors
  • Four LED Diagnostic Indicators
  • Operation to 3 Miles (5km) at 9600 Baud, 1 Mile (1.7km) at 19,200, 0.5 Miles (0.8km) at 57,600
  • Four-Wire Full Duplex, Two-Wire Simplex
  • Self-Powered or Host-Powered
  • Selection of Connectors
  • Wide Operating Temperature Range, 0 to +70°C
  • CE Compliant

Block Diagram

FAQ

Frequently Asked Questions


Can Dataforth provide calibration reports for modules I purchased?
Yes we can provide calibration reports for the modules that you purchased.

You can either
a) visit https://www.dataforth.com/TestDataReport.aspx to search for Test Report Datasheets by Serial Number or
b) you can send us a list of model numbers and their serial numbers to support@dataforth.com

Can I communicate between a two LDM Converters / Line Drivers without DTR (Data Terminal Ready) control signal?
Yes, two LDM Converters / Line Drivers can be setup to communicate between two remote RS-232 terminals with only TD (Transmit Data), RD (Receive Data) and GND (Ground) signals. The setup is possible only if the communication is Simplex (one-way over two-wires) or Full-Duplex (two-way over four-wires). For Half-Duplex (two-way over two-wires) communication DTR control signal is required.

Short DTR line to RLSD (Received Line Signal Detect) on both end of RS-232 terminals at the LDM connectors. The RS-232 terminals at the LDM is a DB-25 connector. For DB-25 connectors, DTR is Pin 20 and RLSD is Pin 8.

If a DB-9 to DB-25 converter is used at the RS-232 terminal then short Pin 4 (DTR) to Pin 1 (RLSD or DCD - Data Carrier Detect) on the 9-pin connector.

Is the LDM35 a suitable replacement for the LDM30?
Please observe the block diagram in the datasheets of the LDM35 and LDM30 modules.

In the block diagram, you can see the direction of space current and mark current through terminals 3 and 4 (TD+ and TD-). Since these currents flow in the opposite direction between the LDM30 and LDM35, the LDM35 cannot be used to replace the LDM30.

We recommend replacing the LDM30 with another LDM30, or you can use the LDM70 as a suitable replacement as well.

Due to resource constraints on my computer, I'm unable to open the three dimensional CAD models provided on your website. Does Dataforth provide two demensional CAD models for download as well?
Two dimensional CAD models can be generated upon customer request. Please contact Customer Service for assistance.
Was this content helpful?    Yes / No

Don't see an answer to your question?

If you have a question that is not answered here, please submit your question using our Online Technical Support Assistance.

Competitive Cross-Reference

  • No cross reference is available.
View Dataforth cross-reference data.
The information available through this competitive cross reference guide are based upon product catalog information obtained from a variety of sources. The competitive cross reference information is being provided to you free of charge for your use. While Dataforth Corp has used reasonable efforts to ensure data accuracy, Dataforth Corp does not guarantee that it is error-free, nor does Dataforth Corp make any other representation, warranty or guarantee that the information is accurate, correct, reliable or up-to-date. Dataforth Corp expressly disclaims all implied warranties regarding this information, including but not limited to any implied warranties of merchantability or fitness for a particular purpose.

This information is provided only as a convenience on an "as is" basis and Dataforth Corp. or its representatives or distributors are not responsible for any incorrect, inaccurate, or incomplete information. You are solely responsible for (1) selecting the appropriate Dataforth products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements.

Price shown is for small quantities. For large quantities, add to cart and submit an RFQ.